Aspirateurs industriels antidéflagrants pour utilisation dans des champs de tirs
Aspirateurs Catégorie 2 antidéflagrants et à l'épreuve de l'inflammation des poussières pour ATEX Zone 1 (Gaz) et ATEX Zone 21 (Poussière)
How you clean the range area is very important. Inadequate and/or inappropriate range cleaning procedures can actually create a greater risk of lead exposure. Perhaps the worst thing you can do is clean the range by dry sweeping. Similarly, compressed air can’t be used to clear floors or other surfaces of accumulated lead. Both procedures will stir up lead dust and increase airborne lead levels and exposures.
As you may know, there are two methods that should be considered for the routine cleaning of your range. One is wet mopping and the other is using a HEPA vacuum system. Both systems prevent settled lead from becoming stirred up and exposing employees to elevated airborne lead levels. However, you should be aware that if you use a wet mop procedure for range cleaning, the water may need to be managed as a hazardous waste. If you plan to use a HEPA vacuum system, make sure it is designed to be explosion proof so unburned or spilled gunpowder isn’t accidentally ignited. All Tiger-Vac vacuum cleaner systems designed for shooting range/shot house maintenance are legally certified explosion proof and dust ignition proof. The HEPA filter may also need to be managed as a hazardous waste. When working on the range the ventilation should be turned on (unless performing work on the ventilation systems or performing other activities where running the ventilation system could create a hazard to the worker.).
Voir notre brochure
Legally Certified Explosion Proof / Dust Ignition Proof - Designed for use in Division 1
Electrically Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.

IECEx Certified
0081
II 2 G/D Ex d IIA T4 Ex tD A21
IP65 – T 120°C
LCIE 03 ATEX 6297
0081
II 2 G/D Ex d IIA T3 Ex tD A21
IP6X – T 200°C
LCIE 03 ATEX 6297
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Designed for the recovery of flammable and toxic powders such as unspent gunpowder and lead contaminants
- Ideal for shooting ranges, army ammunition depots, manufacturers of firearms and pyrotechnic industries
- Single phase explosion proof/dust ignition proof motor
- Available with Manual Filter Shaker (MFS) system
- For dry recovery only
- All stainless steel SAE 304 construction (except cart). Stainless steel cart available
- Detachable recovery tank (DT). Recovery capacity of 6.25 gallons (25 liters)
- Equipped with an SD* polyliner and clip for easy and safe disposal of recovered materials
- Equipped with an SD* 4-wheel cart and tool basket
- Complete static dissipating tool kit and suction hose included
SD* Static Dissipative
Electrically Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.

IECEx Certified
0081
II 2 G/D Ex d IIA T4 Ex tD A21
IP65 – T 120°C
LCIE 03 ATEX 6297
0081
II 2 G/D Ex d IIA T3 Ex tD A21
IP6X – T 200°C
LCIE 03 ATEX 6297
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Designed for the recovery of flammable and toxic powders such as unspent gunpowder and lead contaminants
- Ideal for shooting ranges, army ammunition depots, manufacturers of firearms and pyrotechnic industries
- Single phase explosion proof/dust ignition proof motor
- For dry recovery only. Optional Floater System available for liquid recovery
- All stainless steel SAE 304 construction.
- Recovery capacity of 10.5 gallons (40 liters)
- Equipped with an SD* polyliner and clip for easy and safe disposal of recovered materials
- Equipped with an SD* 4-wheel dolly for easy maneuverability
- Complete static dissipating tool kit and suction hose included
SD* Static Dissipative
Static Free
Electrically Operated
Certifications
Vacuum cleaner classified according to Dust Class B1 (BIA ZH 1/487)
Combustible dusts of the explosion classes St1, St2, St3 in Zone 22 (Previously Zone 11)
II 3 D IP54 T160oC
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- For general cleanup of designated substances such as Asbestos, Lead, Silica, Mold, etc.
- Continuous Duty - Single or 3-phase (TEFC) motor
- Static dissipating and conductive (Category 3 - Zone 22 (Dust))
- Available with Manual Filter Shaker (MFS) with Teflon (PTFE) polyester media (H13)
- Main Cloth Filter and Dralon Pre-Filter are contained within a removable Filter Chamber
- For dry recovery only
- Carriage with suspended motor top (CSMT)
- Stainless steel SAE 430 body and recovery tank
- Detachable recovery tank (DT) for easy disposal of recovered materials. Recovery capacity of 6.6 gallons (25 liters)
- Ready to use: filters and SD* tool kit included
- Equipped with an SD* 4-wheel cart for easy manoeuverability
- Vertical mounting for areas with space constraints. Unit has a small environmental footprint
- Dustless Drill Kit available
SD* - Static Dissipative
TEFC - Totally Enclosed Fan Cooling
Electrically Operated
Certifications
Vacuum cleaner classified according to Dust Class B1 (BIA ZH 1/487)
Combustible dusts of the explosion classes St1, St2, St3 in Zone 22 (Previously Zone 11)
![]()
II 3 D Ex tD A22 IP6X T100oC
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Designed to protect operator from lead exposure
- By-Pass universal motor with a high level of protection against motor sparking hazards
- Static Dissipating and Conductive
- For dry recovery only
- Stainless steel SAE 430 body and recovery tank
- Ready to use: filters and SD* tool kit included
- Equipped with SD* 4-wheels. Optional 2 + 2 cart available
*SD - Static Dissipative
Electrically Operated
Certifications
Vacuum cleaner classified according to Dust Class B1 (BIA ZH 1/487)
Combustible dusts of the explosion classes St1, St2, St3 in Zone 22 (Previously Zone 11)
![]()
II 3 D Ex tD A22 IP6X T100oC
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Designed to protect operator from lead exposure
- By-Pass universal motor with a high level of protection against motor sparking hazards
- Static Dissipating and Conductive
- For dry recovery only
- Stainless steel SAE 430 body and recovery tank
- Equipped with polyliner and clip for easy and safe disposal of recovered materials
- Ready to use: filters and SD* tool kit included
- Equipped with SD* 4-wheels. Optional 2 + 2 cart available
*SD - Static Dissipative
Note:
- Les filtres HEPA - efficacité de 99,995% sur les 0,3 microns - Testé IEST RP-CC001.3 - H14 SIPM selon la méthode EN 1822.
- ULPA Filters - efficacité de 99,999% sur les 0,3 microns - Filtration efficacité de 99,9995% à 0,18 microns - Testé IEST RP-CC001.3 - U15 SIPM selon la méthode EN 1822
- Tous les filtres HEPA / ULPA de Tiger-Vac sont testés DOP lors de l'assemblage, soit en amont ou en aval, à l'intérieur de l'aspirateur.
- Tous les filtres HEPA / ULPA de Tiger-Vac sont assemblés mécaniquement avec 3 boulons et inclus un joint mémoire spécialement conçus afin de prévenir toute fuite pendant la durée de vie du joint d'étanch pour assurer la santé et la sécurité de l'utilisateur final.